Electromagnetic Heating Reactor

Measuring gas Methane (CH4)
Measuring range 0-100,000ppm.m
Alarm type Visible, audible
Response time T90<0.05s

Features

Adopts TDLAS detection principle

Detection distance can be more than 150 meters

Fast response, the alarm will be sent out on the leakage point, no alarm delay

Good selectivity, only response to Methane, effectively avoid the interference of water vapor, automobile exhaust and other gas

Color LCD screen display of gas concentration data

With real-time waveform and digital display functions, optional ranges of ppm.m, LEL.m and VOL.m

Low power consumption design allows continuous monitoring of objects that can be penetrated by light, such as ordinary glass, for a long time

Data can be uploaded to the remote monitoring platform via Bluetooth 

Application

It can be widely used in the city gas transmission and distribution pipeline, oil, petrochemical industry refineries, chemical plants, metallurgical industry, power industry and other places that may produce gas leakage.

  • City Lifeline

  • City Lifeline

  • City Lifeline

  • City Lifeline

Specifications

Measuring gas Methane (CH4)
Measuring range 0-100,000ppm.m
Alarm type Visible, audible
Response time T90<0.05s
Sensitivity 5ppm.m
Sensor life 10 years
Measuring type Laser beam
Alarm type Visible, audible
Audible alarm 85dB @1m
Battery voltage DC3.7V
Working temperature -20℃~+50℃
Working humidity <99%RH (no condensation)
Accessories Belt, screen cover
Option Telescope sight
Working time 8 hours
Explosive-proof degree Ex ib IIB T4 Gb
Ingress Protection IP66
Dimension 220mm×80mm×90mm
Weight About 600g
  • Hot Tags:

Send Message

Related Products

Electromagnetic Hot Water Superheater

Electromagnetic Hot Water Superheater

Electromagnetic Hot Water Superheater

Trax30

Trax30

Trax30 series product adopt high quality gas sensor and MCU technology, has good repeatability and stability. It is widely used in the fields of oil processing plants, chemical factories, metallurgy, power plants etc. With 4-20mA signal output, it can be connected with the central control panel.

ABH210

ABH210

This series of gas detection transmitters adopt the most advanced ultra-large scale integrated circuit technology and are designed by the international standard intelligent technology level.

WD10-IR2

WD10-IR2

WD10-IR2 double IR flame detector is a new type of intelligent fire detection equipment. The detectors uses 2 infrared sensors with different wavelengths with narrow-band filtering.

Electric Heating Pressurized Hot Water Boiler

Electric Heating Pressurized Hot Water Boiler

Electric Heating Pressurized Hot Water Boiler

Electric Heating Vacuum Vulcanizing Tank

Electric Heating Vacuum Vulcanizing Tank

Electric Heating Vacuum Vulcanizing Tank

Leave a Message

Please contact us for free quotation by form below. We promise the quickest response within 24 hours:

Home WhatsApp Mail Inquiry